Touch arm sounds like its measuring the first point but will not proceed to the next point

Touch arm sounds like its measuring the first point but will not proceed to the next point

Problem: cannot get the touch to go from the very first measuring point to the second, and its making the measuring sound. 
Solution: Exit out of everything and make sure that TestTouch is not open in the background
                  if it is then exit TestTouch and open the Touch software.

Cause: TestTouch gains the connection to the touch arm for the computer, if its left open and then the Touch software is opened, the BT connection will never move over to the Touch software it will always stay connected to TestTouch.
    • Related Articles

    • How to Setup Touch Glasses and VNC Server

      Included in this thread there is a PDF on how to obtain the VNC server and get the Glasses connected.
    • 1 Point Coincidence TOUCH Arm Test

      1. Get touch connected and turned on 2. Open TOUCH Program 3. Goto "TEST" 4. Select Probe that you have on 5. Grab a piece of masking tape and put an X on it. 6. Place the piece of masking tape made in Step 5. on the Car, OR framerack, OR 2 post ...
    • Touch - Measuring with mechanical components removed.

      Measuring with mechanical components removed is very easy.  Read the attached document and learn how.
    • Spanesi Touch Update Process 2024-3 (January 12, 2025)

      Perform all Windows Operating System updates prior to any Spanesi Touch updates. Check the current version of the Touch software and vehicle database. Open Spanesi SpA Touch 1.1. Click Settings then View Updates. On the left hand side of the screen ...
    • Spanesi Touch Update Process 2024-4 (April 9th, 2025)

      Perform all Windows Operating System updates prior to any Spanesi Touch updates. Check the current version of the Touch software and vehicle database. Open Spanesi SpA Touch 1.1. Click Settings then View Updates. On the left hand side of the screen ...